Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Cardiology ; (12): 930-934, 2017.
Article in Chinese | WPRIM | ID: wpr-809522

ABSTRACT

Objective@#To compare the value of two 3D imaging reconstruction methods for left atria and pulmonary vein on guiding the catheter ablation for atrial fibrillation (AF).@*Methods@#From January 2014 to January 2017, a total of 100 drug refractory paroxysmal AF patients were divided into left atria direct angiography group (n=50), and indirect angiography group (n=50). 3D CARTO system was applied for mapping and guiding the ablation procedure. Patients assigned to direct angiography group were treated as follows: intraoperative puncture of atrial septum, inject contrast agent directly into the left atrium, conduct left atrial and pulmonary venous rotation angiography, reconstruct three-dimensional image, integrate the image into real-time X-ray system to facilitate circumferential pulmonary vein isolation. Patients assigned into the indirect angiography group were treated as follows: inject contrast agent through the right ventricle, conduct delayed rotation angiography of the left atria and pulmonary vein to guide circumferential pulmonary vein fixation and ablation. The left atrial and pulmonary venous image acquisition, the operation and X-ray exposure time, the success rate and the incidence of complication of the two groups were compared. The patients were followed up for 3-6 months.@*Results@#General clinical characteristics of the two groups were similar(all P>0.05). Ablation was successful in all 100 patients. The operation time[(112.0±21.4)min vs. (134.0±24.3)min]and X-ray exposure time((10.7±4.7)min vs. (15.8±5.2)min)were significantly lower in direct angiography group than in indirect angiography group (both P<0.01). There was no significant difference between the two groups in the immediate (86%(43/50) vs. 82%(41/50), P=0.59) and short-term (76%(38/50) vs. 72%(36/50), P=0.65) success rate and complication rate (1 aneurysm in the direct angiography group, 1 pericardial tamponade in the indirect angiography group). In-hospital mortality was zero percent.@*Conclusion@#It is safe and effective method to guide the radiofrequency catheter ablation of paroxysmal atrial fibrillation by reconstruction 3D image of left atrium and pulmonary vein. Compared with indirect angiography group, direct angiography group can improve the imaging quality of left atrium and pulmonary vein, decrease the X-ray exposure time of the ablation procedure.

2.
Chinese Circulation Journal ; (12): 398-402, 2016.
Article in Chinese | WPRIM | ID: wpr-486382

ABSTRACT

Objective: To explore the role of angiotensin receptor type I (AT1)-calcineurin (CaN) signaling pathway in transient outward potassium ion channel (Ito) remolding in hypertrophic atrial myocytes of neonatal rats. Methods: 1 day old neonatal rats’ atrial myocytes were isolated and the cells were divided into 4 groups:①Control group, normal cells were cultured for 24 h,②Stretching group, the cells were cultured for 24 h with mechanical stretching to induce hypertrophy,③Telmisartan group, the cells were treated by telmisartan at 1 μmol/L for 1 h, then cultured for 24 h and ④Cyclosporin-A (CsA) group, the cells were treated by CsA at 0.25 μg/ml for 1 h, then cultured for 24 h. The ratios of protein/DNA in myocytes were compared between Control group and Stretching group, cell hypertrophy was deifned by mRNA expression of atrial natriuretic peptide (ANP). Ito changes were detected by whole-cell patch clamping technique, proteins expressions of Kv4.3 and CaN A subunit were examined by Western blot analysis. Results: Compared with Control group, Stretching group showed obviously decreased Ito density and Kv4.3 protein expression, while increased CaN A protein expression; Compared with Stretching group, the above effects were reduced in Telmisartan group and CsA group. Conclusion: AT1-CaN signaling pathway was involved in the regulation of Ito channel remodeling in hypertrophic atrial myocytes of neonatal rats.

3.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592757

ABSTRACT

Objective To discuss the clinical value of Mutislice CT angiography (MSCTA)in cervical vascular diseases. Methods 60 patients highly suspected suffering cervical vascular diseases,were implemented 16-slices spiral CT angiography of cervical vascular,and blood vessel reconstruction and analysis were done subsequently. Results 43 cases with cervical vascular abnormality were presented in the 60 patients,who were implemented MSCTA. Positive ratio was 71.7%. 171 pieces vessel stenosis were detected among 240 pieces carotid artery and vertebra artery, and 4 cases carotid artery aneurysm and 1 case AVM were found also. Conclusion MSCTA is a convenient and shortcut modality to inspect cervical vascular diseases, and the blood vessel can be observed 3-dimensionally and in any direction in high quality reconstruction images.

SELECTION OF CITATIONS
SEARCH DETAIL